Certification Record

CUSTOMER CLASS FILE

Huron Window Corporation 8029-02 241201
345 Mountain St S, BUILDING PRODUCTS AND MATERIALS- Windows-
Morden
MB
R6M 1J5
Canada Refer to Class Description for program details

Model/Type        Performance Ratings    ER
Ambiance Series Low Profile Fixed(1) Fixed B7 C5 - - 20 to 44(8) 
Ambiance Series Casement(2) A3 B7 C5 F10 S1  16 to 36(8) 
Ambiance Series Awning(3) A3 B7    C5   F10 S1 15 to 36(8) 
Huron Series Low Profile Fixed(1) Fixed B7 C5 - 20 to 45(8) 
Huron Series Casement(2)     A3 B7    C5   F10 S1 16 to 35(8) 
Huron Series Awning(3) A3 B7    C5  F10 S1 15 to 36(8) 
Huron Series Basement(4) A3 B7    C5  F10 S1 15 to 25(9) 
Beveled Series Double Hung(5) A3 B3 C2 F10 S1 15 to 28(9) 
Beveled Series Single Hung(5) A3/Fixed B3 C3 F10     S1  16 to 30(9) 
Beveled Series Single Slider(6) A3/Fixed B3 C3 F10       S1    16 to 30(9) 

NOTES:

(a)Physical rating:

·         Low Profile Test window size is 1908x1908 mm

·         (2): Casement Test window size is 1625x1117 mm

·         (3): Awning Test window size is 1219x1016 mm

·         (4): Basement Test window size is 1130x668 mm

·         (5): Hung Test window size is 1117x1625mm

·         (6): Single Slider window size is 1625x1117mm.

Casement and awning models could be double or triple glazed.

(b) Energy ratings:

Various glazing options have been used to determine energy ratings those shown under ER represent the lowest to highest rating:

In general for all options spacer used is Silicone Foam and where applicable, low-e used is PPG Sungate 500 and argon gas is 90% argon fill;

·         (8)  8 options used where option 1 is double glazing, clear glases with air infill;  option 2 is double glazing with Low-e (surface 3) and argon; options 3 to 8 are triple glazing where option 3 is with air fill and low-e (5); option 4 air and argon in respective cavities and  low-e(5);  option 6 is with argon in both cavities and  low-e(3 and5); option 7 with argon in both cavities and  low-e(2 and4); and option 8 with air fill and clear glasses.  Lowest ratings in general are in option 1 and highest in options 5 or 6.

·         (9)  2 Options with double glazing are used (option 1 is clear glass and air infill and option 2 low-e on face 3 and argon fill); option 1 has the lower of the two options in all cases.

 